Ultrasonic flowmeters

Stationary
Dnepr-7 - 02.101.1
Controlled environment:
Pure water

It is intended for measurement of the volumetric charge and quantity of water in pressure head pipelines. Gauges are established without incut in the pipeline. It is used for units of the account of thermal energy. It is supplied by the testing simulator. DO from 50 up to 1600 mm.
Stationary
Dnepr-7 - 02.011.1
Controlled environment:
Sewage water

It is intended for measurement of the volumetric charge and quantity of sewage in pressure head pipelines. Gauges are established without incut in the pipeline. It is supplied by the testing simulator. DO from 20 up to 1600 mm.
Stationary
Dnepr-7 - 01.041.1
Controlled environment:
Steam


It is intended for measurement of the volumetric charge and quantity sated pair and other gaseous environments. Gauges are established without incut in the pipeline. It is supplied by the testing simulator. Temperature sated pair up to 200 ° C. DO from 20 up to 700 mm.
Stationary
Dnepr-7 - 05.040.1
Controlled environment:
Fuel

It is intended for ultraprecise measurement of the volumetric charge and quantity of water and any homogeneous liquid in pressure head pipelines with DO 20, 32, 50, 80 mm, including those with as low flow speed as 0,02 m3/hour (0,33 l/m). It is supplied with engraved sensors.
Stationary
Dnepr-7 - 03.011.1
Controlled environment:
Self-flowing pipelines


It is intended for measurement of the volumetric charge and quantity of sewage in free-flow pipelines and collectors. It is supplied: a flowmeter with unprofitable gauges, the block of measurement of a level of filling and the testing simulator. Uses a direct method of measurement of the charge, allowing to exclude influence heads. DO from 100 up to 1600 mm.
Stationary
Dnepr-7 - 01.071.1
Controlled environment:
Oil and black oil


It is intended for measurement of the volumetric charge and quantity of crude oil and black oil in pressure head pipelines. Gauges are established without incut in the pipeline. It is supplied by the testing simulator. DO from 20 up to 1600 mm.
Stationary
Dnepr-Teplocom - 05.070.1
Heat meter


intended for measurement of quantity of thermal energy in internal systems of heat supply with pipelines DO from 15 to 600 mm and water heat carrier, including measurment of polluted cooling liquids. It is supplied: engraved ultrasonic converters, heat meter VKT-7, thermosensors, autonomous power supply for the heat and flow meter. With titanium sensorsq depending on working environment.
Stationary
Dnepr-Teplocom - 05.080.1
Heat meter

intended for measurement of quantity of thermal energy in internal systems of heat supply with pipelines DO from 15 to 600 mm and water heat carrier, including measurment of polluted cooling liquids. It is supplied: engraved ultrasonic converters, heat meter VKT-7, thermosensors, autonomous power supply for the heat and flow meter. With titanium sensorsq depending on working environment.
Stationary
Dnepr-Teplocom - 02.131.1
Heat meter


intended for measurement of quantity of thermal energy in internal systems of heat supply with pipelines DO from 15 to 600 mm and water heat carrier, including measurment of polluted cooling liquids. It is supplied: engraved ultrasonic converters, heat meter VKT-7, thermosensors, autonomous power supply for the heat and flow meter. With titanium sensorsq depending on working environment.
Stationary
Dnepr-Teplocom - 02.141.1
Heat meter


intended for measurement of quantity of thermal energy in internal systems of heat supply with pipelines DO from 15 to 600 mm and water heat carrier, including measurment of polluted cooling liquids. It is supplied: engraved ultrasonic converters, heat meter VKT-7, thermosensors, autonomous power supply for the heat and flow meter. With titanium sensorsq depending on working environment.
Stationary
Dnepr-Teplocom - 01.101.1
Heat meter


It is intended for measurement of quantity of thermal energy in steam systems of a heat supply. It is supplied: a flowmeter with unprofitable gauges heat counter Dnepr-7, gauges of temperature and the testing simulator. DO from 32 up to 700 mm.
Portable
Dnepr-7 - 01.142.2

It is intended for measurement of the volumetric charge and quantity of any liquid, sated pair and other gaseous environments, and also for definition of an installation site of stationary devices. It is supplied notebook, displaying hydraulics, a direction of a stream and schedules of charges. It is used for carrying out of starting-up and adjustment works and audit. For water DO from 20 up to 1600 mm. For pair DO from 20 up to 700 mm.
Portable
Dnepr-7 - 01.121.2

It is intended for measurement of the volumetric charge and quantity of any liquid, sated pair and other gaseous environments, and also for definition of an installation site of stationary devices. It is supplied notebook, displaying hydraulics, a direction of a stream and schedules of charges. It is used for carrying out of starting-up and adjustment works and audit. For water DO from 20 up to 1600 mm. For pair DO from 20 up to 700 mm.
Portable
Dnepr-7 - 02.041.2

It is intended for measurement of the volumetric charge in pressure head pipelines. Gauges are established without incut in the pipeline. It is used for audit of heating systems. DO from 50 up to 1600 mm.
Portable
Dnepr-7 - 02.052.2

It is intended for measurement of the volumetric charge in pressure head pipelines. Gauges are established without incut in the pipeline. It is used for audit of heating systems. DO from 50 up to 1600 mm.